Observation | ONLINE FIRST

Chlorhexidine Gluconate–Impregnated Central Access Catheter Dressings as a Cause of Erosive Contact Dermatitis:  A Report of 7 Cases FREE

Nicole A. Weitz, BA; Christine T. Lauren, MD; Jessica A. Weiser, MD; Nicole R. LeBoeuf, MD; Marc E. Grossman, MD; Katherine Biagas, MD; Maria C. Garzon, MD; Kimberly D. Morel, MD
[+] Author Affiliations

Author Affiliations: Departments of Dermatology (Drs Lauren, Weiser, LeBoeuf, Grossman, Garzon, and Morel) and Pediatrics (Drs Lauren, Biagas, Garzon, and Morel), College of Physicians and Surgeons, Columbia University, New York, New York. Ms Weitz is a medical student at Columbia University School of Medicine.


JAMA Dermatol. 2013;149(2):195-199. doi:10.1001/jamadermatol.2013.903.
Text Size: A A A
Published online

ABSTRACT

Background Chlorhexidine gluconate–impregnated dressings have become widely adopted as a means to reduce the risk for catheter-associated bloodstream infections. These dressings release antiseptic under occlusion onto the skin surrounding catheter insertion sites. Although chlorhexidine gluconate is a known cause of contact dermatitis, the phenotypic range of this adverse effect of chlorhexidine gluconate–impregnated dressings in critically ill patients has not been described.

Observations We report 7 cases of erosive irritant contact dermatitis due to chlorhexidine gluconate–impregnated transparent dressings. Six of these patients were children (age range, 4 months to 2 years); the adult was a critically ill 62-year-old man. Four patients were immunosuppressed after solid organ transplant and all were receiving blood pressure support at the time of this reaction. The insertion sites of femoral catheters were involved in all but 1 case; 3 catheter sites were involved in the adult patient. Results of extensive infectious workups were negative. All lesions resolved with discontinuation of the chlorhexidine gluconate–containing dressings, local wound care, and alternative antimicrobial dressings.

Conclusions Erosive contact dermatitis is an underrecognized complication of chlorhexidine gluconate–impregnated dressings. Health care providers should be aware of this risk, particularly in young children and immunosuppressed and/or critically ill patients, who may be more susceptible to the irritant effects of these dressings. When the dressings are used, patients should be monitored closely for skin breakdown.

Figures in this Article

Chlorhexidine gluconate–impregnated dressings are used to reduce bloodstream infections associated with central access catheters (CACs).1 Chlorhexidine gluconate is a routinely used antiseptic that is bactericidal against gram-negative and gram-positive organisms. Two dressing formulations, a chlorhexidine-impregnated sponge and a transparent adhesive gel pad containing chlorhexidine gluconate, 2%, have been created. They are designed to release the antiseptic material onto the skin surrounding the CAC insertion site under airtight occlusion. Multiple randomized controlled trials have demonstrated marked reductions in the risk for catheter-related infections with these novel dressings.25 Thus, many intensive care units (ICUs) have adopted them as routine care applied after CAC insertion.

Although chlorhexidine gluconate–impregnated dressings have been shown to decrease catheter-related bloodstream infections, little has been reported regarding the adverse cutaneous effects resulting from their prolonged use in critically ill patients and young children in particular. Herein we report 7 cases of erosive contact dermatitis due to chlorhexidine gluconate–impregnated gel pad dressings (Tegaderm CHG; 3M) (Figure 1) observed in our ICUs.

Place holder to copy figure label and caption
Graphic Jump Location

Figure 1. A transparent chlorhexidine gluconate–impregnated gel pad dressing (Tegaderm CHG; 3M) covering a central line on the abdomen of an infant.

REPORT OF CASES

CASE 1

A 6-month-old boy with a history of surgically repaired congenital heart disease required ICU management of pulmonary hypertension and respiratory failure. A dermatologist was consulted 12 days after left femoral CAC placement to evaluate skin irritation surrounding the insertion site. On examination, a rectangular erythematous patch was present in the left groin extending to his anterior left thigh with multiple large erosions covered by fibrinous debris (Figure 2A). The site had been dressed with a chlorhexidine gluconate–impregnated gel pad and changed approximately once every 4 days from the time of insertion. The CAC was removed owing to malfunction, and the patient was treated empirically with systemic broad-spectrum antibacterial, antiviral, and antifungal therapy while awaiting culture results. Gram stain, bacterial culture, direct fluorescent antibody testing, viral culture, potassium hydroxide preparation, and fungal culture from the erosions yielded negative findings. The area was treated with topical antibiotics and nonadherent dressings, with reepithelialization of the erosions during the following week.

Place holder to copy figure label and caption
Graphic Jump Location

Figure 2. Examples of irritant contact dermatitis associated with chlorhexidine gluconate–impregnated dressings. A, A geometric erythematous patch with large erosions covered by fibrinous material surrounds the site of the left femoral venous catheter in a 6-month-old boy (case 1). B, Multiple small ulcers covered with fibrinous debris surround the insertion site of the right internal jugular venous catheter in a 2-year-old girl (case 4). C, One large ulcer with fibrinous exudate lies superior to the insertion site of the right femoral venous catheter in a 1-year-old girl (case 5). D, An erythematous patch with a large erosion covered by yellow fibrinous material surrounds the left femoral venous catheter in a 5-month-old boy (case 6).

CASES 2 TO 7

We evaluated 6 additional cases of geometric erosive dermatitis surrounding CAC insertion sites dressed with chlorhexidine gluconate–impregnated transparent gel pads. The similar clinical findings are described in the Table and Figure 2B-D.

Table Graphic Jump LocationTable. Summary of Clinical Features in the Present Case Seriesa

COMMENT

Chlorhexidine gluconate is a rare but known cause of allergic contact dermatitis (ACD) and irritant contact dermatitis (ICD).6 Several reports have described ACD due to chlorhexidine gluconate, some complicated by anaphylactic shock after its application to intact skin.711 The prevalence of sensitization to chlorhexidine gluconate in positive skin patch test results ranges from 0.47% to 2.7%, with the highest rates in children with atopic dermatitis.12,13 However, the local ICD that is the most frequent adverse reaction to chlorhexidine gluconate exposure in children has not been as thoroughly examined in the literature. Previous reports of ICD after chlorhexidine gluconate exposure in children describe a range of clinical presentations from mild erythema to severe exudative reactions.3,4

We reviewed 7 cases of erosive dermatitis occurring at the sites of CACs dressed with chlorhexidine gluconate–impregnated gel pads changed at approximately weekly intervals (Table). Six of the patients were infants and children ranging in age from 4 months to 2 years. The final patient in our series (case 7), a critically ill 62-year-old immunosuppressed man, presented with cutaneous eruptions similar to those of our 6 pediatric cases at the sites of his 3 CACs. All the patients were severely ill, necessitating care in the ICU and requiring blood pressure support. Four of the 7 patients, including the adult, had received solid organ transplants and were immunosuppressed. Five of the 7 patients died of their underlying illnesses, unrelated to the erosions at their catheter sites, during the same hospital admission.

Our findings are consistent with demographics of earlier reports suggesting that infants are most susceptible to the irritant effects of dressings containing chlorhexidine gluconate. In a randomized study evaluating the efficacy and safety of chlorhexidine gluconate–impregnated dressings in children, local redness developed in 4 subjects, compared with only 1 control subject; removal of the CAC or dressing was not needed, and the erythema resolved with catheter removal.3 All 4 subjects were neonates. In another study comparing povidone-iodine–with chlorhexidine gluconate–containing dressings, 19 of 335 infants who received chlorhexidine gluconate–containing dressings developed severe exudative reactions with erythematous patches extending to the edges of the antimicrobial dressings, which were partially or completely covered by mucopurulent drainage.4 Most episodes (79%) occurred in neonates with a gestational age less than 28 weeks and birth weight less than 1000 g and who were younger than 1 week at the time of CAC insertion. No patient in the povidone-iodine group developed contact dermatitis, and all patients with ICD after the use of chlorhexidine gluconate–containing dressings were switched to povidone-iodine dressings with resolution of the symptoms. Although lower rates of positive findings in catheter tip cultures were seen in the chlorhexidine gluconate group, no difference in the incidence of catheter-related bloodstream infections or bloodstream infections without an identified source was found. These reports suggest that the skin of infants and young children may be more susceptible to irritation by chlorhexidine gluconate than that of older children. Severe ICD in reaction to chlorhexidine gluconate–containing dressings has been reported in adults at a lower rate than in children (5.3 per 1000 catheter insertions), predominantly affecting critically ill patients with multiple-organ failure and skin fragility, as in case 7.2

As a manifestation of the innate immune response, ICD results from the irritant's perturbation of the skin barrier and cytotoxic effects on keratinocytes, inducing a cytokine cascade.14 The susceptibility to ICD depends on endogenous and exogenous factors that culminate in damage to the integrity of the skin barrier and in release of inflammatory cytokines. The patient population described in this report is at greater risk for cutaneous complications given the compromised nature of the skin barrier in pediatric and chronically ill patients and the relative immunodeficiency from the immature nature of the immune systems of young children, iatrogenic immunosuppression, or the combination of the two.15,16 The relative hypoperfusion of the skin in these patients requiring blood pressure support also may have compounded their susceptibility to ICD.

Among known exogenous risk factors for ICD are the concentration and potency of the irritant, duration and site of skin exposure, occlusion over the application site, and ambient temperature and humidity.16,17 The reported erosive dermatoses can be attributed to the occlusive nature of the dressings, the continual skin exposure, and the local concentrations of chlorhexidine above the reference range achieved on the skin surface.4 Such a reaction has never been described in infants receiving full-body chlorhexidine gluconate skin cleansing without occlusive dressings.18

In most of the cases reported herein, the insertion sites of femoral catheters were involved, affecting the groin and proximal thigh. The susceptibility to ICD varies with the region of skin exposed, with the thigh being the most vulnerable.17 In case 5, the patient had an identical dressing on the arm without any evidence of irritation, underscoring the importance of the body site as a factor for the development of ICD. The site of skin exposure is only one factor contributing to the risk for ICD, and 2 patients had erosive lesions at other sites. Case 4 had an erosive lesion on the neck, another intertriginous site. Her young age and immunosuppression after a heart transplant also may have contributed to a lower threshold for this reaction. Case 7 developed erosive lesions at the sites of his 3 CACs, including the groin, neck, and wrist. This patient may have been particularly susceptible to the irritant effects of CHG because he also developed these lesions after the shortest interval after catheter placement among the other patients described (8 days).

Because the patients most likely to be exposed to chlorhexidine gluconate–containing dressings are severely ill and often immunocompromised, they are most vulnerable not only to the irritant sequelae of this exposure but also to infectious processes that could mimic ICD. All cultures and other microbiological evaluations from the sites in our patients yielded negative results. However, these crucial investigations should not be overlooked when managing erosive or ulcerative lesions at the site of a CAC. Many of our patients received systemic broad-spectrum antimicrobial coverage at the time of presentation; for those who did not, however, such coverage was added while awaiting culture results.

The management of erosive ICD hinges on the recognition and removal of the chemical or the physical irritant and wound care. In all the patients described, discontinuation of chlorhexidine gluconate treatment under occlusion was recommended. Alternative antimicrobial dressings were used with clinical improvement in the lesions in 5 of 7 patients. In 2 cases, the CACs were removed owing to malfunction of the catheters involved. In all cases, the erosions and ulcerations resolved during the following 1 to 2 weeks with appropriate wound care.

We infer that these cases represent ICD rather than ACD because of the erosive nature of the lesions, the occlusive nature of the dressings, and the occurrence of these reactions in infants, in whom ACD is rare. In addition, this reaction occurred at some but not all sites of application in patients with multiple chlorhexidine gluconate–containing dressings. No patient demonstrated evidence of pruritus, including the adult, although the severity of these patients' conditions likely prevented them from manifesting this symptom. None of the cases involved the use of tinted chlorhexidine, with which prior cases of ACD have been reported.19,20 No patient developed erosions at other sites, including sites of other adhesives, and cases 6 and 7 improved while using the clear acrylic dressings without chlorhexidine gluconate, supporting our suspicion that chlorhexidine gluconate may be the component causing this reaction. Given the critical conditions of these patients and the erosive nature of the expected reactions, certain confirmatory tests, such as repeated open-application testing or patch testing, were not performed.

Given the known variability in the presentation of ICD, the cases presented herein probably represent more severe irritant reactions to chlorhexidine gluconate–impregnated dressings. We cannot determine whether these presentations represent the severe end of the same spectrum as the mild erythematous reactions described in the literature or a distinct phenotype that develops under certain clinical circumstances.

CONCLUSIONS

Erosive contact dermatitis at the site of CACs can pose a significant danger to patients because it has the potential to provide a larger portal for entry to infection than the catheter alone. One should consider whether central access is crucial for life-sustaining measures and, if so, what lengths are appropriate to maintain a clean, well-protected CAC insertion site. Intensive care units must evaluate the risks and benefits of infection control protocols in each patient with care, particularly in infants or young children and immunosuppressed patients, who may be most susceptible to the irritant effects of occlusive CHG dressings. When these dressings are used to prevent CAC infections, providers should monitor skin closely for the development of erosive contact reactions.

ARTICLE INFORMATION

Correspondence: Kimberly D. Morel, MD, Department of Dermatology, College of Physicians and Surgeons, Columbia University, 161 Fort Washington Ave, 12th Floor, New York, NY 10032.

Accepted for Publication: August 25, 2012.

Published Online: November 19, 2012. doi:10.1001/jamadermatol.2013.903

Author Contributions: All the authors had full access to all the data in the study and take responsibility for the integrity of the data and the accuracy of the data analysis. Study concept and design: Lauren, Weiser, LeBoeuf, and Morel. Acquisition of data: Weitz, Morel, Lauren, Weiser, LeBoeuf, Grossman, Garzon, and Morel. Analysis and interpretation of data: Weitz, Lauren, Weiser, Biagas, Garzon, and Morel. Drafting of the manuscript: Weitz, Lauren, Weiser, LeBoeuf, and Garzon. Critical revision of the manuscript for important intellectual content: Lauren, LeBoeuf, Biagas, Garzon, and Morel. Administrative, technical, or material support: LeBoeuf. Study supervision: Lauren, Grossman, Biagas, and Morel.

Conflict of Interest Disclosures: Dr Morel reports receiving grant support from Astellas Pharma US, Inc, and Dr Lauren reports receiving grant support from the National Philoptochos Society. Neither of these disclosures is relevant to the subject of this report.

REFERENCES

Hodge D, Puntis JWL. Diagnosis, prevention, and management of catheter related bloodstream infection during long term parenteral nutrition.  Arch Dis Child Fetal Neonatal Ed. 2002;87(1):F21-F24
PubMed   |  Link to Article
Timsit JF, Schwebel C, Bouadma L,  et al; Dressing Study Group.  Chlorhexidine-impregnated sponges and less frequent dressing changes for prevention of catheter-related infections in critically ill adults: a randomized controlled trial.  JAMA. 2009;301(12):1231-1241
PubMed   |  Link to Article
Levy I, Katz J, Solter E,  et al.  Chlorhexidine-impregnated dressing for prevention of colonization of central venous catheters in infants and children: a randomized controlled study.  Pediatr Infect Dis J. 2005;24(8):676-679
PubMed   |  Link to Article
Garland JS, Alex CP, Mueller CD,  et al.  A randomized trial comparing povidone-iodine to a chlorhexidine gluconate–impregnated dressing for prevention of central venous catheter infections in neonates.  Pediatrics. 2001;107(6):1431-1436
PubMed   |  Link to Article
Roberts BL, Cheung D. Biopatch: a new concept in antimicrobial dressings for invasive devices.  Aust Crit Care. 1998;11(1):16-19
PubMed   |  Link to Article
Gimenez-Arnau AM. Occupational contact dermatitis  In: Johanson JD, Frosch PJ, Lepoittevin JP, eds. Contact Dermatitis. Heidelberg, Germany: Springer; 2011:841-851
Lauerma AI. Simultaneous immediate and delayed hypersensitivity to chlorhexidine digluconate.  Contact Dermatitis. 2001;44(1):59
PubMed  |  Link to Article   |  Link to Article
Ebo DG, Stevens WJ, Bridts CH, Matthieu L. Contact allergic dermatitis and life-threatening anaphylaxis to chlorhexidine.  J Allergy Clin Immunol. 1998;101(1, pt 1):128-129
PubMed   |  Link to Article
Torricelli R, Wüthrich B. Life-threatening anaphylactic shock due to skin application of chlorhexidine [correspondence].  Clin Exp Allergy. 1996;26(1):112
PubMed   |  Link to Article
Goon AT, White IR, Rycroft RJ, McFadden JP. Allergic contact dermatitis from chlorhexidine.  Dermatitis. 2004;15(1):45-47
PubMed   |  Link to Article
Le Corre Y, Barbarot S, Frot AS, Milpied B. Allergic contact dermatitis to chlorhexidine in a very young child.  Pediatr Dermatol. 2010;27(5):485-487
PubMed   |  Link to Article
Mailhol C, Lauwers-Cances V, Rancé F, Paul C, Giordano-Labadie F. Prevalence and risk factors for allergic contact dermatitis to topical treatment in atopic dermatitis: a study in 641 children.  Allergy. 2009;64(5):801-806
PubMed   |  Link to Article
Liippo J, Kousa P, Lammintausta K. The relevance of chlorhexidine contact allergy.  Contact Dermat. 2011;64(4):229-234
Link to Article
Rustemeyer T, van Hoogstraten IMW, von Bomberg BME,  et al.  Mechanisms of irritant and allergic contact dermatitis. In: Johanson JD, Frosch PJ, Lepoittevin JP, eds. Contact Dermatitis. Heidelberg, Germany: Springer; 2011:43-75
Nikolovski J, Stamatas GN, Kollias N, Wiegand BC. Barrier function and water-holding and transport properties of infant stratum corneum are different from adult and continue to develop through the first year of life.  J Invest Dermatol. 2008;128(7):1728-1736
PubMed   |  Link to Article
Zhai H, Meier-Davis SR, Cayme R, Shudo J, Maibach H. Irritant contact dermatitis: effect of age.  Cutan Ocul Toxicol. 2012;31(2):138-143
PubMed   |  Link to Article
Frosch PJ, John SM. Clinical aspects of irritant contact dermatitis. In: Johanson JD, Frosch PJ, Lepoittevin JP, eds. Contact Dermatitis. Heidelberg, Germany: Springer; 2011:305-327
Chapman AK, Aucott SW, Milstone AM. Safety of chlorhexidine gluconate used for skin antisepsis in the preterm infant.  J Perinatol. 2012;32(1):4-9
PubMed   |  Link to Article
 Material Safety Data Sheet 3MTM TegadermTM w/CHG (1657, 1658, 1659, 1660). February 8, 2011. http://multimedia.3m.com/mws/mediawebserver?mwsId=SSSSSuUn_zu8l00x4xt958tBlv70k17zHvu9lxtD7SSSSSS--. Accessed May 25, 2012
McCleskey PE. Dermatitis to FD&C yellow No. 6 dye in orange antiseptic solution.  Arch Dermatol. 2011;147(9):1124-1125
PubMed   |  Link to Article

Figures

Place holder to copy figure label and caption
Graphic Jump Location

Figure 1. A transparent chlorhexidine gluconate–impregnated gel pad dressing (Tegaderm CHG; 3M) covering a central line on the abdomen of an infant.

Place holder to copy figure label and caption
Graphic Jump Location

Figure 2. Examples of irritant contact dermatitis associated with chlorhexidine gluconate–impregnated dressings. A, A geometric erythematous patch with large erosions covered by fibrinous material surrounds the site of the left femoral venous catheter in a 6-month-old boy (case 1). B, Multiple small ulcers covered with fibrinous debris surround the insertion site of the right internal jugular venous catheter in a 2-year-old girl (case 4). C, One large ulcer with fibrinous exudate lies superior to the insertion site of the right femoral venous catheter in a 1-year-old girl (case 5). D, An erythematous patch with a large erosion covered by yellow fibrinous material surrounds the left femoral venous catheter in a 5-month-old boy (case 6).

Tables

Table Graphic Jump LocationTable. Summary of Clinical Features in the Present Case Seriesa

References

Hodge D, Puntis JWL. Diagnosis, prevention, and management of catheter related bloodstream infection during long term parenteral nutrition.  Arch Dis Child Fetal Neonatal Ed. 2002;87(1):F21-F24
PubMed   |  Link to Article
Timsit JF, Schwebel C, Bouadma L,  et al; Dressing Study Group.  Chlorhexidine-impregnated sponges and less frequent dressing changes for prevention of catheter-related infections in critically ill adults: a randomized controlled trial.  JAMA. 2009;301(12):1231-1241
PubMed   |  Link to Article
Levy I, Katz J, Solter E,  et al.  Chlorhexidine-impregnated dressing for prevention of colonization of central venous catheters in infants and children: a randomized controlled study.  Pediatr Infect Dis J. 2005;24(8):676-679
PubMed   |  Link to Article
Garland JS, Alex CP, Mueller CD,  et al.  A randomized trial comparing povidone-iodine to a chlorhexidine gluconate–impregnated dressing for prevention of central venous catheter infections in neonates.  Pediatrics. 2001;107(6):1431-1436
PubMed   |  Link to Article
Roberts BL, Cheung D. Biopatch: a new concept in antimicrobial dressings for invasive devices.  Aust Crit Care. 1998;11(1):16-19
PubMed   |  Link to Article
Gimenez-Arnau AM. Occupational contact dermatitis  In: Johanson JD, Frosch PJ, Lepoittevin JP, eds. Contact Dermatitis. Heidelberg, Germany: Springer; 2011:841-851
Lauerma AI. Simultaneous immediate and delayed hypersensitivity to chlorhexidine digluconate.  Contact Dermatitis. 2001;44(1):59
PubMed  |  Link to Article   |  Link to Article
Ebo DG, Stevens WJ, Bridts CH, Matthieu L. Contact allergic dermatitis and life-threatening anaphylaxis to chlorhexidine.  J Allergy Clin Immunol. 1998;101(1, pt 1):128-129
PubMed   |  Link to Article
Torricelli R, Wüthrich B. Life-threatening anaphylactic shock due to skin application of chlorhexidine [correspondence].  Clin Exp Allergy. 1996;26(1):112
PubMed   |  Link to Article
Goon AT, White IR, Rycroft RJ, McFadden JP. Allergic contact dermatitis from chlorhexidine.  Dermatitis. 2004;15(1):45-47
PubMed   |  Link to Article
Le Corre Y, Barbarot S, Frot AS, Milpied B. Allergic contact dermatitis to chlorhexidine in a very young child.  Pediatr Dermatol. 2010;27(5):485-487
PubMed   |  Link to Article
Mailhol C, Lauwers-Cances V, Rancé F, Paul C, Giordano-Labadie F. Prevalence and risk factors for allergic contact dermatitis to topical treatment in atopic dermatitis: a study in 641 children.  Allergy. 2009;64(5):801-806
PubMed   |  Link to Article
Liippo J, Kousa P, Lammintausta K. The relevance of chlorhexidine contact allergy.  Contact Dermat. 2011;64(4):229-234
Link to Article
Rustemeyer T, van Hoogstraten IMW, von Bomberg BME,  et al.  Mechanisms of irritant and allergic contact dermatitis. In: Johanson JD, Frosch PJ, Lepoittevin JP, eds. Contact Dermatitis. Heidelberg, Germany: Springer; 2011:43-75
Nikolovski J, Stamatas GN, Kollias N, Wiegand BC. Barrier function and water-holding and transport properties of infant stratum corneum are different from adult and continue to develop through the first year of life.  J Invest Dermatol. 2008;128(7):1728-1736
PubMed   |  Link to Article
Zhai H, Meier-Davis SR, Cayme R, Shudo J, Maibach H. Irritant contact dermatitis: effect of age.  Cutan Ocul Toxicol. 2012;31(2):138-143
PubMed   |  Link to Article
Frosch PJ, John SM. Clinical aspects of irritant contact dermatitis. In: Johanson JD, Frosch PJ, Lepoittevin JP, eds. Contact Dermatitis. Heidelberg, Germany: Springer; 2011:305-327
Chapman AK, Aucott SW, Milstone AM. Safety of chlorhexidine gluconate used for skin antisepsis in the preterm infant.  J Perinatol. 2012;32(1):4-9
PubMed   |  Link to Article
 Material Safety Data Sheet 3MTM TegadermTM w/CHG (1657, 1658, 1659, 1660). February 8, 2011. http://multimedia.3m.com/mws/mediawebserver?mwsId=SSSSSuUn_zu8l00x4xt958tBlv70k17zHvu9lxtD7SSSSSS--. Accessed May 25, 2012
McCleskey PE. Dermatitis to FD&C yellow No. 6 dye in orange antiseptic solution.  Arch Dermatol. 2011;147(9):1124-1125
PubMed   |  Link to Article

Correspondence

CME
Meets CME requirements for:
Browse CME for all U.S. States
Accreditation Information
The American Medical Association is accredited by the Accreditation Council for Continuing Medical Education to provide continuing medical education for physicians. The AMA designates this journal-based CME activity for a maximum of 1 AMA PRA Category 1 CreditTM per course. Physicians should claim only the credit commensurate with the extent of their participation in the activity. Physicians who complete the CME course and score at least 80% correct on the quiz are eligible for AMA PRA Category 1 CreditTM.
Note: You must get at least of the answers correct to pass this quiz.
You have not filled in all the answers to complete this quiz
The following questions were not answered:
Sorry, you have unsuccessfully completed this CME quiz with a score of
The following questions were not answered correctly:
Commitment to Change (optional):
Indicate what change(s) you will implement in your practice, if any, based on this CME course.
Your quiz results:
The filled radio buttons indicate your responses. The preferred responses are highlighted
For CME Course: A Proposed Model for Initial Assessment and Management of Acute Heart Failure Syndromes
Indicate what changes(s) you will implement in your practice, if any, based on this CME course.
Submit a Comment

Multimedia

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Articles Related By Topic
Related Collections
PubMed Articles